A balanced snow load is the even layer of snow a roof carries across its surface. A drift is the extra snow that piles up against a step, wall or parapet, where wind carries snow over the high part of a roof and drops it in the sheltered corner beside it. On a lower roof next to a taller one, the drift can be several times the balanced load, which is why a drift check often decides the design of that lower roof. This guide explains the difference, sets out the formulas the RoofHelm drift engine uses, and works through three step cases with the engine's actual outputs.
The balanced load: the even layer
On a sloped roof the balanced load, Ps, is the flat-roof snow load reduced by the slope factor Cs. It assumes the snow lies in a uniform layer and that wind does not move it. Ps is the number a roof is normally sized for, and it is the starting point for any drift calculation. In the worked cases below the lower roof has a balanced load of 28 psf.
The drift: snow that piles at a step
When a lower roof sits against a higher one, the upper roof acts as a fetch. Wind sweeps snow off its surface and deposits it on the lower roof next to the wall. The drift is a wedge of extra snow that sits on top of the balanced layer. Two things set its size: the ground snow load, which controls how much snow is available to move, and the length of the upper roof, which controls how much snow is fed into the corner. The height of the step limits how tall the drift can grow, because the drift cannot rise above the clear height of snow left between the balanced layer and the top of the step.
The formulas the calculator uses
The drift engine works through a fixed sequence of steps. Snow density is gamma = 0.13 × Pg + 14, capped at 30 pcf, where Pg is the ground snow load in psf. The balanced snow depth is hb = Ps ÷ gamma, in feet. The clear height is hc = step height − hb. The leeward drift height, from the upper roof of length Lu in feet, is hd = 0.43 × Lu^(1/3) × (Pg + 10)^(1/4) − 1.5. A windward drift is 0.75 times the same expression using the lower roof length Ll. The governing drift is the larger of the two, and it is capped at hc. The drift width is 4 × hd when the drift fits under hc. The peak surcharge is hd × gamma, and the peak load at the step is Ps plus that surcharge.
A note on the code edition
The drift-height relation above is the classic form used in earlier editions of ASCE 7 and is the form this calculator implements. ASCE 7-22 revised the leeward drift equation, so the value your adopted code gives may differ from the calculator's number. Treat the drift figures here as a planning estimate. Confirm the equation in the edition your building department has adopted, and have a licensed engineer check any drift that a permit depends on.
Worked case 1: a 6 ft step under a 100 ft upper roof
The inputs are a ground snow load of Pg = 40 psf, a balanced load of Ps = 28 psf on the lower roof, a step height of 6 ft, an upper roof length of Lu = 100 ft and a lower roof length of Ll = 50 ft. The engine returns a snow density of 19.2 pcf and a balanced depth of 1.46 ft. The clear height is therefore 4.54 ft. The leeward drift height is 3.81 ft and the windward drift height is 2.03 ft, so the leeward case governs. Because 3.81 ft is less than 4.54 ft, the drift is not truncated. Its width is 15.23 ft, its surcharge is 73.1 psf and the peak load at the step is 101.1 psf.
That peak is 3.6 times the 28 psf balanced load, and it is concentrated in a band about 15 ft wide next to the wall rather than spread across the roof. A design that sizes the whole lower roof for 28 psf would miss it entirely. A design that sizes the whole roof for 101 psf would waste material everywhere else.
Worked case 2: the same step under a 30 ft upper roof
Keep every input from case 1 except the upper roof length, which drops from 100 ft to 30 ft. The leeward drift height falls to 2.05 ft, a little above the windward 2.03 ft, so the leeward case still governs. The width is 8.21 ft, the surcharge is 39.42 psf and the peak load is 67.42 psf. That is 2.4 times the balanced load.
Shortening the upper roof by 70 per cent cut the peak by about a third. The drift height follows the cube root of the fetch length, so a long roof does not add drift in direct proportion. The surcharge falls by 46 per cent, from 73.1 psf to 39.42 psf, but the peak falls by a third, because the 28 psf balanced load under it does not change.
Worked case 3: a 3 ft step that cannot hold a full drift
Now keep case 1 but reduce the step height to 3 ft. The clear height is 1.54 ft. The leeward drift wants to be 3.81 ft tall, which is more than the clear height, so the drift is truncated. The engine caps its height at 1.54 ft and widens its base instead. The width comes out at 12.33 ft, the surcharge at 29.6 psf and the peak load at 57.6 psf.
A shorter step gives a lower peak here, 57.6 psf against 101.1 psf, because the clear height caps the drift. The step height and the balanced depth together set how much of the full drift fits. The clear height also sets the width: the truncated drift is 12.33 ft wide, against 15.23 ft for the full drift in case 1.
When a drift can be ignored
Drift does not need to be checked where the clear height is small compared with the balanced depth. The calculator uses a threshold of hc divided by hb below 0.2 to mark a drift as not required. Take a step of only 1.5 ft under the same loads. The clear height falls to 0.04 ft, the ratio is about 0.03, and the engine marks the drift as not required. Its peak is then 28.8 psf, which is barely above the balanced load. Check the threshold in your own code edition before relying on it.
Drift against balanced: which governs?
The balanced load applies over the whole roof. The drift load applies only to the zone beside the step, and it is added to the balanced load there. For the lower roof in case 1 the designer carries 101.1 psf at the step and 28 psf elsewhere, and the drift width tells you how far the higher value reaches. Drift is therefore a local case, not a replacement for the balanced load. Most designs need both, and the step is where the drift case governs. The same logic applies to the sliding load from a sloped upper roof, which we cover separately in our sliding snow loads guide.
For a gable roof the wind-driven unbalanced case is a different check, covered in our unbalanced snow load guide. Drift and unbalanced loads can both apply to the same roof, so check each case and take the largest value for each member.
What the calculator does not check
The drift engine works from the four numbers you enter: ground load, balanced load, step height and the two roof lengths. It does not model parapets with capture walls, irregular multi-level roofs, drift against a roof with obstructions, or the connections and members that carry the drift. Those need an engineer. The engine's result is a transparent estimate of one load case, which is the reason it shows every intermediate value rather than a single number.
Frequently asked questions
The questions below come up most often when people compare drift with the balanced load. Each answer is a planning answer. Confirm the value against your adopted code before you build.
Is the drift load added to the balanced load?
Yes, at the step. The peak load in the drift zone is the balanced load plus the drift surcharge. Outside the drift width the balanced load alone applies.
Why is the drift so much bigger than the balanced load?
Because the drift concentrates the snow that the upper roof would otherwise shed across a wide area into a narrow zone. In case 1 the balanced layer is only 1.46 ft deep, while the drift adds 3.81 ft of snow at its peak.
Do walls and parapets create drift too?
Yes. Snow moves against walls and parapets in the same way, and the same family of formulas applies, using the windward case. The capture and parapet provisions in your code are more detailed than the simple step case shown here, so check them directly.
Do I need an engineer to check a drift?
If the drift affects a permit, yes. A licensed engineer should confirm the code equation, the factors and the connections. The calculator gives a transparent planning figure, and the engineer's review turns it into a design.
Summary
A drift is the extra snow that piles against a step, and it can roughly double or triple the balanced load in a narrow zone beside the wall. The RoofHelm drift engine shows each step: density, balanced depth, clear height, drift height, width, surcharge and peak. Three cases show the main behaviour. A longer upper roof increases the drift, but not in direct proportion. A short step truncates the drift and widens it. A small step may not need a drift check at all. For the full method, read our guide to snow drift loads on roofs, and check the edition your building department has adopted before you rely on any figure.
Sources
ASCE/SEI 7, Minimum Design Loads and Associated Criteria for Buildings and Other Structures, is published by the American Society of Civil Engineers (https://www.asce.org/publications-and-news/asce-7). Its snow drift provisions in Chapter 7 are the basis for the formulas above, and the edition your jurisdiction adopts controls. The FEMA roof snowdrift design guide discusses drift at roof steps and walls (https://www.fema.gov/sites/default/files/2020-07/fema_roof_snowdrift_design_guide.pdf). Structure magazine's article on snow and rain loads in ASCE 7-22 summarises the changes between editions (https://www.structuremag.org/article/snow-and-rain-loads-in-asce-7-22/).
Get your design roof snow load in seconds with the free ASCE 7-22 calculator.
Open the calculatorRelated guides
- Snow Drift Loads on Roofs (ASCE 7 §7.7) Made Simple: How snow drifts form at roof steps, parapets and walls, why they can be the governing load case, and how to size the drift surcharge.
- Unbalanced Snow Load on Gable Roofs: Unbalanced snow load governs gable roofs when wind piles snow on one side. ASCE 7 §7.6 requires a check; here's how to calculate the design case.
- Sliding Snow Loads (ASCE 7 §7.9) Explained: When a slippery roof sheds snow, the mass lands on the lower roof or walkway below. ASCE 7 §7.9 sizing for sliding snow surcharge, explained step by step.
- Ground Snow Load vs Roof Snow Load: The Difference: Why roof snow load is usually less than ground snow load, and the exposure, thermal and importance factors that connect them.
- When a Snow Load Calculator Isn't Enough (and What to Do Next): What a roof snow load calculator computes, where it stops being enough, a worked example of how one input moves the design load, and who to involve for a permit.
- What a Roof Snow Load Calculation Report Should Show: A roof snow load report is the document a building official or engineer checks. Here is what it should contain, a worked 6:12 gable example, and what it cannot replace.