A roof engineering monograph

Maryland Roof Snow Load Calculator

Ground snow load across the populated parts of Maryland runs roughly 20 to 35 psf (moderate). The calculator below is pre-loaded with a typical Maryland value of 25 psf. Change it to your confirmed site value and adjust the roof.

Case-study state. The coastal plain is moderate; western Maryland's mountains are higher. Mountain and high-elevation sites are ASCE 7 "case study" zones: the ground snow load is driven by elevation and can be several times the lowland value, so confirm your exact site with the ASCE Hazard Tool or your building department.
Design snow load17.5 psf

The worksheet

ASCE 7-22
12"Design load17.5 psf
Fig. A · the roof section at 18.4°, snow blanket scaled to the design load.
Design roof snow load · balanced
17.5psf

At 18.4° the §7.3.4 minimum does not apply, so the balanced load of 17.5 psf governs.

26,250 lb total on 1,500 sq ft of roof plan

Flat Pf
17.5psf
0.7·Ce·Ct·Is·Pg
Sloped Ps
17.5psf
Cs 1
Minimum Pm
n/a
slope ≥ 15°
Rain-on-snow
0psf
§7.10
Unbalanced load · §7.6.1 gable
may govern

Large gable roof (W > 20 ft): windward side at 0.3·Ps, leeward side at Ps plus a drift surcharge from the ridge.

Windward
5.25 psf
Leeward base
17.5 psf
Leeward peak
34.91 psf

surcharge 17.41 psf over 8.09 ft · hd 1.75 ft · γ 17.25 pcf

How this was calculated

Flat-roof load Pf = 0.7 × Ce(1) × Ct(1) × Is(1) × Pg(25) = 17.5 psf. Sloped-roof balanced load Ps = Cs(1) × Pf = 17.5 psf.

Ground snow load, Pg25 psfsite input
Exposure factor, Ce1Table 7.3-1
Thermal factor, Ct1Table 7.3-2
Importance factor, Is1Table 1.5-2
Slope factor, Cs1Fig. 7.4-1
Snow density, γ17.25 pcfEq. 7.7-1
Settled depth at design load12 indesign ÷ density
  • 01Estimated snow density ≈ 17.25 pcf, so 17.5 psf is roughly 12 in of settled snow.
  • 02The §7.6.1 unbalanced (leeward-drift) case is computed above for this gable/hip roof; at roof steps, parapets and walls also check drift loads (§7.7) with the drift calculator, plus sliding snow (§7.9) onto anything below.
  • 03Ground snow load Pg is set by your local building department / the ASCE 7 Hazard Tool. Always confirm the value for your exact site before you build or submit.
Next stepSuppliers

Reduce the load on an existing roof

Your design roof snow load is 17.5 psf. If the design load is close to your roof's capacity, the cheapest fix is to keep snow off it. These are the tools that do that.

Some links are affiliate links: if you buy through them we may earn a commission at no extra cost to you. These are starting points, not engineering endorsements. Always confirm a product's rated snow load meets the design load above.

Finding your exact Maryland ground snow load

The number above is a planning value, not a permit value. For Maryland, get your site's design ground snow load from the ASCE 7 Hazard Tool or your local building department. Many Maryland jurisdictions adopt a published county or town value. Because elevation drives the value here, two nearby sites can differ a lot, so always use the value for your exact address.

Calculate by roof type