A roof engineering monograph

Oklahoma Roof Snow Load Calculator

Ground snow load across the populated parts of Oklahoma runs roughly 5 to 15 psf (low). The calculator below is pre-loaded with a typical Oklahoma value of 10 psf. Change it to your confirmed site value and adjust the roof.

Low ground snow load statewide.
Design snow load7 psf

The worksheet

ASCE 7-22
5"Design load7 psf
Fig. A · the roof section at 18.4°, snow blanket scaled to the design load.
Design roof snow load · balanced
7psf

At 18.4° the §7.3.4 minimum does not apply, so the balanced load of 7 psf governs.

10,500 lb total on 1,500 sq ft of roof plan

Flat Pf
7psf
0.7·Ce·Ct·Is·Pg
Sloped Ps
7psf
Cs 1
Minimum Pm
n/a
slope ≥ 15°
Rain-on-snow
0psf
§7.10
Unbalanced load · §7.6.1 gable
may govern

Large gable roof (W > 20 ft): windward side at 0.3·Ps, leeward side at Ps plus a drift surcharge from the ridge.

Windward
2.1 psf
Leeward base
7 psf
Leeward peak
18.7 psf

surcharge 11.7 psf over 6.13 ft · hd 1.33 ft · γ 15.3 pcf

How this was calculated

Flat-roof load Pf = 0.7 × Ce(1) × Ct(1) × Is(1) × Pg(10) = 7 psf. Sloped-roof balanced load Ps = Cs(1) × Pf = 7 psf.

Ground snow load, Pg10 psfsite input
Exposure factor, Ce1Table 7.3-1
Thermal factor, Ct1Table 7.3-2
Importance factor, Is1Table 1.5-2
Slope factor, Cs1Fig. 7.4-1
Snow density, γ15.3 pcfEq. 7.7-1
Settled depth at design load5 indesign ÷ density
  • 01Estimated snow density ≈ 15.3 pcf, so 7 psf is roughly 5 in of settled snow.
  • 02The §7.6.1 unbalanced (leeward-drift) case is computed above for this gable/hip roof; at roof steps, parapets and walls also check drift loads (§7.7) with the drift calculator, plus sliding snow (§7.9) onto anything below.
  • 03Ground snow load Pg is set by your local building department / the ASCE 7 Hazard Tool. Always confirm the value for your exact site before you build or submit.
Next stepSuppliers

Reduce the load on an existing roof

Your design roof snow load is 7 psf. If the design load is close to your roof's capacity, the cheapest fix is to keep snow off it. These are the tools that do that.

Some links are affiliate links: if you buy through them we may earn a commission at no extra cost to you. These are starting points, not engineering endorsements. Always confirm a product's rated snow load meets the design load above.

Finding your exact Oklahoma ground snow load

The number above is a planning value, not a permit value. For Oklahoma, get your site's design ground snow load from the ASCE 7 Hazard Tool or your local building department. Many Oklahoma jurisdictions adopt a published county or town value.